安装保温板 |
添加时间:2019/3/11 15:22:45 浏览次数: |
1)标准板规格尺寸为300*300,对角线误差小于3mm,如需切割可采用小型切割锯切割,保温板尺寸允许偏差为±2。 1) Standard plate size is 300*300, diagonal error is less than 3 mm, small cutting saw can be used to cut if necessary, and the allowable deviation of insulation plate size is +2. 2)网格布翻包:门窗洞口、变形缝两侧等处粘网格布,总宽度约200,翻包部分宽度为80,具体做法如下:网格布裁剪长度为180加板厚。首先在翻包部位抹长度为80宽度为2的专用粘结剂,然后压入80长的网格布,余下的甩出备用。 2) Mesh cloth turning-over: the total width of the mesh cloth is about 200, and the width of the turning-over part is 80. The concrete method is as follows: the length of the mesh cloth cutting is 180 and the thickness of the plate is 180. Firstly, a special binder with a length of 80 and a width of 2 is applied to the turning part, then 80 long mesh cloth is pressed into it, and the rest is thrown out for reserve. 3)将配置好的专用粘结剂涂抹在复合发泡水泥板的背后,粘结剂压实厚度约为3,为保证粘结牢固,最好采用满沾法,也可采用条粘法和条点法。 3) Apply the special binder to the back of the composite foamed cement board. The compaction thickness of the binder is about 3. In order to ensure the firm bond, it is better to adopt full-dip method, strip-stick method and strip-point method. 4)条粘法:用齿口镘刀将专用粘结剂水平方向均匀的抹在发泡水泥板上,条宽10,厚度10,中距50。 4) Strip bonding method: the special bonding agent is evenly applied on the foamed cement board with a dental trowel in horizontal direction, with a strip width of 10, a thickness of 10 and a mid-distance of 50. 5)条点法:用抹子在每块板周边及中间抹专用粘结剂,再在发泡水泥板分隔区内抹直径为50,厚度为10的灰饼。 5) Strip-point method: use plaster to apply special binder around and in the middle of each board, then plaster 50-diameter and 10-thickness gray cake in the partition area of foamed cement board. 6)将抹好专用粘结剂的保温板迅速粘贴在墙面上,以防止表面结皮而失去粘结作用。 6) Insulation boards with special binder will be quickly pasted on the wall to prevent the surface from crusting and losing the bonding effect. 7)发泡水泥保温板粘上墙后,应用2米靠尺压平操作,保证其平整度及粘贴牢固,板与板之间要挤紧,不得有缝,因切割不直形成的缝隙,用粘结剂塞入并抹平。每粘完一块板,应将挤出表面的专用粘结剂清除。 7) After the foamed cement insulation board is bonded to the wall, it shall be leveled by a 2-meter foot to ensure its smoothness and firm adhesion. The Board shall be squeezed tightly between the board tongdiaop.71ix.comshusongdair.37ix.com.cnguanzhuang.37ix.com.cn ceshi.37ix.com.cnshuichuli.37ix.com.cn feishui.37ix.com.cnand the board, and no seams shall be allowed. The seams formed by the incomplete cutting shall be plugged in and smoothed with a binder. The special binder on the extruded surface should be removed after each board has been bonded. 8)发泡水泥板粘贴应分段自下而上沿水平方向横向铺贴,每排板应错缝1/2板长,局部最小错缝不得小于100。 8) The foamed cement board should be laminated horizontally from bottom to top, with 1/2 length of staggered joints in each row, and the minimum local staggered joints should not be less than 100. |
上一页 挤出吹塑 |
下一页 保温一体板 |
Copyright © 技术支持:遨游网络