保温板粘贴及表面处理的注意事项
1.标准尺寸的保温板1200×600×25。挤塑保温板需预先涂刷界面剂干燥后待用。
1. standard size of heat preservation board 1200 x 600 * 25. The extruded insulation board should be pre painted and the interface agent should be dried before use.
2.先沿着外墙散水标高标出散水水平线,如有变形缝时,应标出变形缝及变形缝宽度。
2. first apron apron along the exterior elevation mark of horizontal lines, such as deformation joints, deformation and deformation of joint shall be marked with slit width.
3.在垂直表面上安装保温板时,应从墙面的基部及坚固、永久的或临时的支撑处开始。
3. when installing an insulation board on a vertical surface, start from the base of the wall and the solid, permanent or temporary support.
4. 翻包网格布:粘贴保温板前先切割窄幅网格布做翻包网格布。
4. turn over the mesh cloth: before sticking the heat preservation board, cut the narrow mesh cloth to make the mesh cloth.
5. 条带法粘贴保温板:用符合规范要求的带锯齿不锈钢抹子涂抹配制好的粘结胶浆条带状,粘结胶浆的粘结面积与保温板的面积之比不低于50%。抹浆时保温板侧边应保持清洁,不得粘有胶浆。
5. a paste insulation board: to meet the requirement of serrated stainless steel trowel smear glue strip preparation. The bonding area of glue and insulation board area of not less than 50%. When applying the slurry, the side of the heat preservation board should be kept clean and should not be sticky.
6.保温板抹完粘结胶浆后,立即将板平贴在已施工过翻包网格布的基层上滑动就位。粘贴时应轻柔、均匀挤压,保证与墙体充分粘结。
6. insulation board wipe glue, immediately board flat on the construction over mesh cloth base sliding bag in place. When sticking, it should be extruded gently and evenly to ensure full bonding with the wall.
7.为了保证板面的平整度,应随时用一根长度不小于2米的靠尺进行压平操作。保温板应自下而上沿水平方向横向铺贴,每排板应错缝搭接1/2板长。
7., in order to ensure the flatness of the surface, it should be used at any time with a length of not less than 2 meters by the foot of the flat operation. The insulation board should be laid horizontally from bottom to top, and each row of plates shall be spliced with 1/2 plates.
8.为配合保温系统表面粘贴面砖对平整度的要求,粘贴保温板时墙面拉通线控制。
8. with the insulation surface system of tile flatness requirements, control wall pull line paste insulation board.
9.在墙面转角处,保温板垂直缝应交错搭接,并保证墙角垂直度。接缝距洞口四角距离应大于等于200mm。
9., at the corner of the wall, the insulation board vertical seam should be staggered overlap, and ensure the verticality of the corner. The distance between the seams and the four corners of the hole shall be greater than or equal to 200mm.